Tutaj znajdziesz informacje o dostępnych konfiguracjach jednostek FP-Safe.
FP-Safe Controller
|
 |
Part number AFSC1605 The FP-Safe controller contains 16 redundant digital inputs as well as 4 positive switching, redundant outputs O2 to O5. Three other outputs can be freely configured.
Up to 5 safety-related functions can be configured, which include emergency stop, protection cover, permission, two-hand control, motion monitoring with proximity switches for speeds up to 1200Hz.
|
|
|
FP-Safe Controller with Transistor I/O Expansion Unit
|
 |
Part number AFSCP2410 This combination contains 24 redundant digital inputs, 4 positive switching, redundant outputs and 13 freely configurable outputs.
A maximum of 7 safety-related functions can be configured.
|
|
|
FP-Safe Controller with Relay Expansion Unit
|
 |
Part number AFSCR1613 This combination contains 16 redundant digital inputs, 4 redundant and 3 freely configurable positive switching outputs as well as 4 safety relay outputs. Each of the relay output consists of 2 redundant contacts and 1 signaling contact
A maximum of 5 safety-related functions can be configured.
|
|
|
FP-Safe Controller with Motion Monitoring Unit
|
 |
Part Number AFSCM2207 This combination contains 22 redundant digital inputs, 4 redundant and 7 freely configurable positive switching outputs. In addition, 2 inputs are available for 2 incremental measuring systems. The motion monitoring unit can monitor 2 drives and achieves the standardized Safe Stop1 (SS1) function. Both TTL and sine/cosine signals can be processed.
A maximum of 7 safety-related functions can be configured. In addition, the following motion monitoring functions are implemented:
- Standstill monitoring
- Position monitoring
- Rotation speed monitoring
- Direction monitoring
- Brake monitoring
|
|
|
FP-Safe Controller with Transistor I/O Expansion Unit and Motion Monitoring Unit
|
 |
Part number AFSCPM3012 This combination contains 30 redundant digital inputs, 4 positive switching, redundant outputs and 17 freely configurable outputs. In addition, 2 inputs available for 2 incremental measuring systems.
|
|
|
FP-Safe Controller with Relay Expansion Unit and Motion Monitoring Unit
|

|
Part number AFSCRM2215 This combination contains 22 redundant digital inputs, 4 positive switching, redundant outputs, 7 freely configurable outputs, 2 inputs for 2 incremental measuring systems and 4 safety relay outputs.
|
|
|
FP-Safe Controller with Relay Expansion Unit and Transistor I/O Expansion Unit
|

|
Part number AFSCRP2418 This combination contains 24 redundant digital inputs, 4 positive switching, redundant outputs, 13 freely configurable outputs and 4 safety relay outputs.
|
|
|
FP-Safe Controller with Relay Expansion Unit, Motion Monitoring Unit and Transistor I/O Expansion Unit
|

|
Part number AFSCWH3020 This combination contains 30 redundant digital inputs, 4 positive switching, redundant outputs, 17 free configurable outputs, 2 inputs for 2 incremental measuring systems and 4 safety relay outputs.
|
|
|
Cables
|

|
- Connecting cable between FP-Safe controller and FP-series PLC via COM port (3-pin), 0.5m
Part number CABMODPLC111D
- Connecting cable between FP-Safe controller and FP-series PLC via COM port (9-pin), 0.5m
Part number CABMODPLC211D
- Connecting cable between FP-Safe controller and FP-series PLC via tool port (mini-DIN), 0.5m
Part number AFS8TP
- Programming cable for FP-Safe controller, Sub-D (9 pin, male), 3m
Part number AFS8PG9
|
|
|
FP-Safe Configurator
|
The software tool FP-Safe Configurator works with Windows XP, Vista and Windows7 and requires a minimum of 512MB RAM. Hardware configuration, circuit diagram and rack diagnosis comprise the three main user tabs in the configurator. The software can be downloaded free of charge. If you cannot start the FP-Safe Configurator after installation, please update the Jave Runtime Environment on your computer: http://www.java.com/.
|